Heat Transfer Analysis of Stationary Bed Materials in a CFB Boiler after a Sudden Power Failure

Yuge Yao,Ling Jiang,Boyu Deng,Man Zhang,Yang Zhang,Hairui Yang,Junfu Lyu
DOI: https://doi.org/10.1016/j.fuproc.2020.106587
IF: 8.129
2021-01-01
Fuel Processing Technology
Abstract:Compared to a pulverized coal boiler, a circulating fluidized bed (CFB) boiler may face greater risk if a sudden power failure accident happens due to the massive bed materials in its main loop. In this study, a numerical simulation is conducted to analyze the heat transfer process of the stationary bed materials and estimate the bed temperature based on a real sudden power failure accident that happened in a 170 t/h CFB boiler. The simulation results are consistent well with the measurement data of three measuring points, which indicates that the simulation results are reliable. The simulation results show that the stationary bed materials continuously dissipate heat but the cooling trends in different areas of the bed materials are different. The average bed temperature is estimated to reach 729.2 degrees C at the end time of the simulation. It is also found that the thermal conductivity of the bed material is the major influencing factor of the bed temperature and heat dissipation process after a sudden power failure, while the effect of the emissivity of the bed material on the bed temperature is slight.