Detection and analysis of corrosion and failure of urban buried steel-made gas pipeline

Guohua Chen,Xinzhi Song,Juncheng Xu,Haosheng Wen,Jinbiao Yuan
2006-01-01
Abstract:Based on China's energy policy, the urban buried gas pipeline is expanding progressively. However, pipeline failure due to corrosion occurs every year, resulting in considerable direct and indirect losses. An excavation pipeline project was carried out in Southern China. To find the cause of corrosion. the soil environment, the coating's failure and etch pits on the pipe were detected and analyzed. It is shown that soil along the pipeline was seriously corroded. This can be attributed to three factors. They are soil moisture content, stray current interference and soil resistivity. The means of remedy are considered by focusing attention on the external load, craft process. corrosion configuration and electrochemical cell. In particular, field observation shows that etch pits are developed mostly on the upper half of the pipe. in contrast to the classic theory of oxygen concentration cell. Countermeasures were recommended.