Micro Gas Cyclone Design and Performance Evaluation to Collect Dust Particles

Masoumeh Mofarrah,Shuran Li,Keping Yan
2018-01-01
Abstract:The objective of this study is to develop a particle collector by using a micro gas cyclone with a body diameter of 10 mm. Design and performance of a cyclone separator is determined by collection efficiency and pressure drop. The behavior of a rectangular inlet-type cyclone for relatively high solid loading rates is reported in this study. For different solid loading flow rates varying from 11.7 to 16.7 liter per min, pressure drop and collection coefficient were evaluated through simulation and experimental work. The experimental part of this study was conducted using Snifter MA+ device. Since the Snifter MA+ is designed to handle flows which are approximated by laminar conditions and the flow regime within the cyclone is mostly turbulent, in order to achieve a suitable performance, the flow in the cyclone should be controlled to be close to laminar conditions. Given these circumstances, the highest cyclone efficiency was recorded for the lowest flow rate and in turbulent condition. The obtained efficiency shows that the cyclone has a reliable performance. As flow rate decreases, pressure drop reduces as well. In order to investigate the pressure drop behavior, velocity and flow trajectories for different flow rates, SOLIDWORKS software, which is applied for drawing and also for simulation was utilized to simulate the model. The simulation results show that by increasing the flow rate, pressure drop also increases.
What problem does this paper attempt to address?