The Effect of Inlet Velocity, Gas Temperature and Particle Size on the Performance of Double Cyclone Separator

Rajdeep Sardar,Jinho Oh,Mirae Kim,Jung-Eon Lee,Seungho Kim,Kyung Chun Kim
DOI: https://doi.org/10.1016/j.cep.2023.109469
IF: 4.264
2023-06-24
Chemical Engineering and Processing - Process Intensification
Abstract:In this present study, the effect of inlet velocity, gas temperature on pressure drop and the effect of particle size on the collection efficiency under different operating conditions are demonstrated for a double cyclone separator, which mainly consists of a 2D2D and 1D3D cyclone in series arrangement. The experiment of pressure drop measurement for different inlet gas velocities in the range of 11-23 m/sec are conducted and it is observed that the pressure drop increase with an increase in gas velocity, which is also validated with CFD results using RSM model and well-established theoretical models. The numerical simulation is also performed for different gas temperature in the range of 300-1100 K . The prediction shows that the pressure drop decrease gradually with increasing the gas temperature, which also gives a better agreement with empirical correlations. The collection efficiency has been estimated for different particle size in the range of 1-10 μm at u = 23 m/sec , by CFD approach. It is noted that the efficiency of single cyclone is very poor for fine particles (<5 μm ) but adding a 1D3D cyclone in series with a 2D2D cyclone separator, the pressure drop is reduced more and the overall separation efficiency is improved in a comprehensive way.
energy & fuels,engineering, chemical
What problem does this paper attempt to address?