Numerical Performance Investigation of a Side‐outlet Cyclone for Particulate Matter and Polymer Powder Separation

Jeffrey Z. Duran,Rommel Thompson G. Gabon,Maurice O. Licdan,Eugene B. Caldona
DOI: https://doi.org/10.1002/ceat.202300076
IF: 2.2148
2024-02-01
Chemical Engineering & Technology
Abstract:A cyclone with a side‐outlet configuration was analyzed by computational fluid dynamics simulation and validated with experimental results. The renormalization group k‐ε model indicated a pressure drop of 80.8412 Pa and separation efficiency of 45.48 %. The operating pressure drop was one‐third of the mathematical model result, while separation efficiency was 15 % lower than the experimental value. The side‐outlet cyclone, featuring a novel geometric design with a lateral gas outlet, proves advantageous in space‐constrained environments compared to traditional cyclones with top gas outlets. Herein, a cyclone separator with a side‐outlet configuration was numerically investigated using the renormalization group k‐ε model and pressure drop and separation efficiency as the performance parameters. Simulation results revealed that the side‐outlet cyclone operates at a low to moderate pressure drop of 80.8412 Pa, with a removal efficiency of 45.48 %. The operating pressure drop was found to be only one‐third of the computed pressure drop from mathematical modeling, with a removal efficiency 15 % lower than the experimental value. With varying cyclone design modifications, suitable experimental procedures and measuring approaches are desirable to further accurately corroborate these results.
engineering, chemical
What problem does this paper attempt to address?