Studies on the Striations in T8 Fluorescent Lamps

Juan BIAN,Shan-duan ZHANG,Yue-qun LIU,Shao-long ZHU
DOI: https://doi.org/10.3969/j.issn.0427-7104.2000.02.017
2000-01-01
Abstract:T8 fluorescent lamp is one of the high-efficient energy-saving illuminating light sources. But at relatively low ambient temperature and small discharge current,there often appeared striations in the lamps,which seriously disturbed the illuminating. It is the precondition of solving problem to understand the cause of the stri ations and its characteristics. From basic discharge plasma equations,a dispersion equation of non-uniform plasma column is derived, from which the criteria for the appearance of the striations and the striation parameters, including frequency, phase velocity and time increment rate are obtained. Experimentally study of T8 lamps show that the measured striation parameters are in reasonable agreement with theoretical calculation.
What problem does this paper attempt to address?