Electrical and Optical Characteristics of Electrodeless Lamp

WANG Chang-quan,ZHANG Gui-xin,DONG Jin-yang,SHAO Ming-song,WANG Xin-xin,WANG Zan-ji
DOI: https://doi.org/10.13296/j.1001-1609.hva.2011.09.016
2011-01-01
Abstract:In order to study the methods to enhance the efficacy of electrodeless lamp,volt-ampere characteristics,illuminance and emission spectrum have been investigated in home-built electrodeless lamp experimental system with an electrodeless lamp in shape like QL 85 lamp.The results show that lamp current increases as lamp voltage increases in non-discharge,the current decreases first and then increases as the voltage increases in discharge.The illuminance of electrodeless lamp increases linearly with discharge power increasing,and it decreases linearly with power decreasing.The emission spectrum is different for different bulb and lighting time.The spectrum of Ar 811.5 nm,76.5 nm,750.4 nm and Hg 313.2 nm decrease with lighting time.While the intensity of Hg 407.8 nm increases with lighting time.
What problem does this paper attempt to address?