Measurement and Analysis of the Steady-state Impedance Characteristics of High-frequency Electrodeless Lamp

SHAO Mingsong,HUANG Songling,ZHAO Wei
DOI: https://doi.org/10.3969/j.issn.1003-6520.2013.04.023
2013-01-01
Abstract:To investigate the impedance of electrodeless lamp under stable operation,we set up an experimental platform to perform measurement.Processing the measurement results,we obtained and analyzed the impedance.Firstly,we summarized and compared three major different equivalent models of electrodeless lamp under stable operation mode,from which the Babat model was selected for processing experimental data.Then considering the characteristic of the impedance,using Nerone's measurement results,we set up a modified experimental platform,on which,the input voltage and input current of an electrodeless lamp under different input powers were measured.Finally,according to the measured data and Babat model,the plasma impedance was calculated.Analyses of the obtained impedance show that,with the increasing power,the plasma impedance decreases,but the coupling coefficient of electrodeless lamp increases.Moreover,the dynamic impedance of electrodeless lamp under stable operation mode is negative at low power,but it is positive at high power due to the intensification of skin effect.This results validate the Eckert's theory of electrodeless lamp's positive impedance characteristic at high power,meanwhile it falsifies the Shinomiya's theory of absolute negative impedance for electrodeless lamps.
What problem does this paper attempt to address?