Power Balance in the Positive Column of Narrow Bore (T2) Fluorescent Lamps

Qiuyi Han,Hao Jiang,Shaolong Zhu,Shanduan Zhang,Graeme Lister,Tzvetelina Petrova
DOI: https://doi.org/10.1088/0022-3727/41/14/144008
2008-01-01
Journal of Physics D Applied Physics
Abstract:Experimental measurements of the electric field and absolute radiance of 254 nm radiation in the positive column of Hg - Ar discharges, corresponding to T2 (outer diameter 7 mm) fluorescent lamps (FLs) are presented. The discharges were operated with 5 Torr argon filling pressure, for discharge currents 20 - 200mA and cold spot temperatures 20 - 80 degrees C. These narrow bore discharges are ` highly loaded', with current densities up to an order of magnitude higher than in larger radius standard FL, and mercury depletion at the axis due to radial cataphoresis can be severe. The cold spot temperature for a maximum production of 254 nm radiation is found to be around 50 degrees C, compared with similar to 40 degrees C for standard FL. The measurements are compared with the results of a numerical model. The model results are also used to provide a power balance for the positive column, showing the relative importance of all power dissipation mechanisms (radiation, gas heating and particle diffusion to the wall of the discharge).
What problem does this paper attempt to address?