A NEW CALCULATION METHOD FOR LARGE-DIAMETER-TUBULAR-PILE BEARING CAPACITY

LI Yiwen,LI Boan,LI Jianqiang,ZHOU Jian
DOI: https://doi.org/10.3969/j.issn.1000-6915.2012.z1.087
2012-01-01
Abstract:Based on the imperial college pile(ICP) method,a new method is proposed to calculate the bearing capacity of large-diameter-tubular-pile,in which the contribution of soil plug is considered.However the inner pile friction is not taken into account due to the small value,not full-length distributed and conservative consideration.In this approach,the end resistance is the average value of tip resistance from the pile tip to the depth of 2 times of the pile diameter.In view of the unpopularity of ring shear test,the peak value of direct shear test is used for the friction angle of the interface by amplification of 1.2,which is verified through test results.The radial effective stress is very important in bearing capacity calculation,and a simplified method with a few parameters is put forward.This new approach is much simpler than ICP method,and could have satisfactory estimations if compared with α-method,Randolph methods and VF method.The test results prove that the new method is reliable.
What problem does this paper attempt to address?