Investigation of Velocity of Square Cyclone with Accelerating Inlet

Yugang BAI,Junfu LU,Qing LIU,Guangxi YUE,Baosen LIU,Yanping YANG,Long YU,Minghua MA
DOI: https://doi.org/10.3969/j.issn.1005-0930.1999.03.012
1999-01-01
Abstract:Square cyclone is one of the new separator that is used in circulating fluidized bed boilers. Its performance and scaling up potential is excellence for compact design with low manufacture cost. In order to insure the operating parameters, such as the velocity of inlet, the investigation was carried out in a cold test rig with separator cross section 700mm×700mm. The experimental result shows that the effect of inlet velocity on collection efficiency is connected with the structure of separator. In a reasonable structure and inlet velocity of 22.5m·s -1 case, the cut size d 50  is 27μm, the critical size d 99  is 127μm, and the resistance coeffcient is 3.9.