Influence of Inlet Structure on Separation Efficiency of Cyclone Separators

SUN Sheng,ZHOU Hao,QIU Kunzan,DONG Kang,CEN Kefa
DOI: https://doi.org/10.3969/j.issn.1674-7607.2013.05.007
2013-01-01
Abstract:Taking the 135 MW circulating fluidized bed boiler as an object of study,a cyclone separator cold-state test setup was built in the scale of 1:10,with which the influence of inlet duct structure(angular-transition and smooth-transition) and entrance inclination angle(15°,30°,45°) on the separation efficiency of the cyclone separator was studied.Results show that the separation efficiency of cyclone separator with angular-transition inlet duct is higher than that with smooth transition inlet duct under same working conditions;the separation efficiency firstly increases and then decreases with the rise of entrance inclination angle;the variation law of classification efficiency with inlet duct structure and entrance inclination angle agrees well with that of the total separation efficiency.
What problem does this paper attempt to address?