RESEARCH ON ASH- CLINKER DEPOSITION PERFORMANCE IN WATER - COOLED BOT TOM ASH HOP PER WHILE BURNERS TILTING DOWN

周昊,池作和,岑可法
DOI: https://doi.org/10.3969/j.issn.1002-3364.2001.04.007
2001-01-01
Abstract:The tilting-type burners commonly used in large boilers with tangential corner firing to regulate the reheater steam temperature have many advantages, such as large range of temperature regulation, sensitivity of adjustment, simple structure, without the necessity to increase the additional heat surface and the power consumption etc, hence the said burners have enjoyed extensive application. But, partial overtemperature of the reheater can be caused by slagging in the furnace in the process of operation. When tilting down burners are used to regulate the reheater temperature, excessive tilting-down angle may lead the flame to dash into the bottom ash hopper, resulting in clinker formation within the hopper, initiating severe accident of clinkering. Therefore, the ash and clinker deposition performance in the bottom ash hopper under different conditions of burner tilting, including burner in horizontal position, burner evenly and unevenly tilting down, as well as ash and clinker deposition having occurred in the bottom ash hopper, has been studied. The results obtained have certain reference value for design and operation of tilting-type burners.
What problem does this paper attempt to address?