Experimental Investigation on a New Semi-Dry Flue Gas Desulfurization Method with Multi-Fluid Alkaline Spray Generator

周月桂,王冬福,章明川,王雷,于娟,陈开潮,缪正清
DOI: https://doi.org/10.3321/j.issn:1000-6761.2004.05.021
2004-01-01
Abstract:A new semi-dry FGD method of simple and compact system and high efficiency is firstly put forward named as multi-fluid alkaline spray generator FGD method. The FGD test rig is built up to investigate the colliding activation efficiency between the sorbent particles and spraying droplets in the prefixed alkaline spray generator and the effect of various factors on SO_2 removal efficiency. The experimental results show that the colliding activation efficiency between the sorbent particles and the spraying droplets in the prefixed alkaline spray generator may reach about 70%, which is markedly higher than the 25% colliding activation efficiency in in-duct injection FGD. And the SO_2 removal efficiency can reach 65% to 70% when Ca/S mole ratio is 1.5(2.0, the approach to adiabatic saturation temperature is 10℃~15℃ and the flue gas residence time is 2.25 seconds, which is higher than that of in-duct injection FGD at the same conditions. Compared with spray dry absorber FGD, it overcomes the complex slurrying system and avoids the clogging and abrasion of slurrying spray nozzles because it only sprays thinner water droplets to activate sorbents. Figs 5 and refs 7.
What problem does this paper attempt to address?