Electrical Performance And Carbon Deposition Differences Between The Bi-Layer Interconnector And Conventional Straight Interconnector Solid Oxide Fuel Cell

Min Yan,Pei Fu,Qiuyang Chen,Qiuwang Wang,Min Zeng,Jaideep Pandit
DOI: https://doi.org/10.3390/en7074601
IF: 3.2
2014-01-01
Energies
Abstract:Carbon deposition considered in a solid oxide fuel cell (SOFC) model may be influenced by the operating voltage, inlet water/methane ratio, working temperature and pressure, inlet molar fraction of fuel and so on. The effects of these parameters in a planar SOFC implementing a novel bi-layer interconnector are not well understood. This paper is focused on the numerical study of carbon deposition and electrical performance of a bi-layer interconnector planar SOFC. The results illustrate that the electrical performance of the bi-layer interconnector SOFC is 11% higher than that of the conventional straight interconnector SOFC with initial state. After 120 days of operation, the electrical performance of the bi-layer interconnector SOFC has a slight decrease and more carbon deposit because of the increased electrochemical reaction rate. However, these differences minimize if higher operating voltages are involved.
What problem does this paper attempt to address?