Mechanical Performance of In-service Composite Insulators

WANG Jia-fu,LIANG Xi-dong,SHEN Qing-he,FAN Ju,HU Xiao-li
DOI: https://doi.org/10.13336/j.1003-6520.hve.2011.05.033
2011-01-01
Abstract:To evaluate the mechanical performances of in-service composite insulators,we experimentally researched the mechanical failing and dynamic loads on about 150 pieces of in-service inner-wedged,outer-wedged and crimped composite insulators.Experimental results show that,after more than ten years' service,inner-wedged composite insulators do not show significant decrease in mechanical performances;the residual mechanical strength of outer-wedged composite insulators has a large dispersivity,and the mechanical reliability of outer-wedged composite insulator is poor;crimped composite insulators have high mechanical performances and the mechanical performances of crimped composite insulator are reliable.The test results provide a reliable experimental guide for evaluating the mechanical reliability of in-service composite insulators.
What problem does this paper attempt to address?