Quick Harmonics Extraction Based on Pure Digital Signal Processing Technology for Three-Phase Shunt APF

张亮,蔡旭
DOI: https://doi.org/10.3969/j.issn.1006-6047.2010.06.013
2010-01-01
Abstract:A three-phase harmonic current detector based on pure digital signal processing technology is proposed,which adopts the harmonics detection principle based on instantaneous reactive power theory with better real time performance.The three-phase digital PLL and IIR lower-pass digital filters are designed to realize the quick extraction algorithm of three-phase harmonic current.To ensure the better real time performance,master-slave type dual DSP+CPLD configuration is applied with the float point DSP TMS320-F28335 and an additional highly accurate 16-bit sampling unit.The experimental results of the prototype show the design is effective.