A Single-phase Harmonic Current Detecting Method Based on Phase-shifted Cancellation
CHEN Le,LIAN Jian-yang,ZHANG Jing,CHEN Guo-zhu
DOI: https://doi.org/10.3969/j.issn.1000-100x.2011.06.015
2011-01-01
Abstract:In order to solve the problem that the 100 Hz component is difficult to be filtered out with traditional in-stantaneous harmonics detecting method in single phase system,an improved harmonic current detecting method based on phase-shifted cancellat.This method can eliminate the second wave of fundamental wave extraction theoretically,so it makes the design of the low-pass filter easier.The traditional method of harmonic current detecting is firstly intro-duced and then an improved method based on phase-shift cancellation is put forward.Through the digital simulation and experiment,the characteristics are analyzed and compared.The results show that the low-pass filter can be de-signed in the higher cut-off frequency,meanwhile extraction and the dynamic response turned to be perfect.