A NEW METHOD FOR REAL-TIME DETECTING HARMONICS AND REACTIVE CURRENTS IN SINGLE-PHASE CIRCUIT

Jiang Bin,Yan Gangfeng,Zhao Guangzhou
DOI: https://doi.org/10.3321/j.issn:1000-1026.2000.21.009
2000-01-01
Abstract:In order to simplify the detection of harmonics and instantaneous reactive currents in single-phase circuit, the current in single-phase circuit is decomposed and a new method for such a purpose is proposed. Firstly, the single-phase current is multiplied by unit sinusoidal and cosinoidal signals with the same frequency of that of circuit voltage respectively and then sent to two low pass filters. Secondly, the outputs of these two low pass filters are again multiplied by the unit sinusoidal and cosinoidal signals to get the reactive and active currents. Lastly, by subtracting the active current thus obtained from the original current, the harmonics and reactive currents can be detected. The function of phase lock loop (PLL) in this method is analyzed in detail and the preconditions of simplifying the algorithm by omitting it are presented. Simulation and experimental results show that harmonics and instantaneous reactive currents in single-phase circuit can easily be precisely detected in real-time by using this simple method.
What problem does this paper attempt to address?