Fracture Analysis of ZG270-500 Cast Steel Lifting Instrument

WANG Xiao-hong,XU Lin-min,JIANG Li
DOI: https://doi.org/10.13251/j.issn.0254-6051.2009.09.019
2009-01-01
Abstract:The chemical composition,hardness,microstructure and fracture morphology of ZG270-500 cast-steel of cracked lifting instrument were detected and analyzed.The results show that Widmanstatten structure in the steel is the major fracture cause of lifting instrument.Coarse crystalline and pores are also observed in the cast steel,and they can decrease the mechanical properties of the steel.The Widmanstatten structure can be removed by normalizing at 870 ℃ and the impact energy and hardness of the steel reach up to 23.5 J and 170 HBS,respectively,which meets the standard GB 11352—1989.