The Contact Resistance And Arc Erosion Behavior Of Separable Cp-Nb-Cr/Cu-Cd Electrical Contact Material

Y. S. Cui,L. Zhen,Y. Wang,W. Z. Shao,V. V. Ivanov
DOI: https://doi.org/10.4028/0-87849-456-1.886
2007-01-01
Key Engineering Materials
Abstract:Cp-Nb-Cr/Cu-Cd electrical contact material, which contains 1.7wt.% of Cd, 0.5wt.% of Cp (man-made diamond particles), 2.0 wt.% of Nb and 0.7 wt.% of Cr, was fabricated by powder metallurgy process. The contact material was installed in different ac contactors covering current range from 40 to 630A. While tested under AC-4 electrical load, the electrical contact material was worn out gradually by repeated electrical arc, and microstructure of the arc-affected surface layer changed dramatically. Mechanism of arc erosion process and contact resistance fluctuation was discussed by corresponding microstructure observation and chemical composition analysis of the surface layer. Cp-Nb-Cr/Cu-Cd electrical contact material is capable to be used in 63 similar to 250A ac contactors under AC-4 working conditions.
What problem does this paper attempt to address?