Detecting methods of reactive power, harmonic and negative-sequence current in electrified railway systems

Zhuo Sun,Xinjian Jiang,Dongqi Zhu
2003-01-01
Abstract:In order to detect the harmonic currents, reactive power and negative-sequence currents in traction power system, two detecting methods based on FBD-method, direct- and indirect-method, are proposed in this paper. In direct-method, current is analyzed based on voltage waveform. The waveform of power current is same to the voltage waveform, so the detecting results are influenced by the voltage. Direct-method suits to the situation that the voltage is stable and has no distortion. In indirection-method, a reference voltage is generated by PLL, the waveform of power current is same to the reference voltage waveform, so detecting results aren't affected by the voltage waveform. There is no Park transformation in direct-method and indirect-method, so the algorithm is simpler than the instantaneous reactive power theory, and they suit to single- even poly-phase circuit. Simulation results and experimental results based on prototype active power quality compensator proved the detecting methods.
What problem does this paper attempt to address?