Calculation of the Flow Rate Deviation Factor of a Boiler Water-wall When the Pr essure Drop of Water/steam Two-phase Flow has been Taken into Account

Dong YANG,Ting-kuan CHEN,Ren-hu TANG,Lin-zhi LIU,Guo-qing YANG
DOI: https://doi.org/10.3969/j.issn.1001-2060.2001.02.016
2001-01-01
Abstract:Based on the principle that there exists an equal pressure drop for a tube with average parameters and another one with deviation parameters the authors have wo rked out an iterative procedure for determining the flow rate deviation factor η1 of a boiler water-wall. This procedure has taken into account the pressur e dro p of both the steam/water two-phase friction resistance and the local resistanc e. In comparison with the method now often used by boiler makers the method reco m mended in the present paper allows to reflect the influence of heat load and the evaporating section length, etc on the flow rate deviation factor. The above tw o methods have been respectively employed to calculate the water-wall flow rate deviation factor of a 400 t/h coal-fired once-through boiler installed at Qinl in g Power Plant, which has been operating at 50% of rated load. Thanks to the abov e calculations an underlying basis has been provided for conducting due hydrodyn amic adjustments to the above-cited boiler during its low-load operation.