Measurement of Void Fraction of High Pressure Steam Water Two-Phase Flow in Vertical Upward Ribbed Tube

zhu xiaojing,bi qincheng
DOI: https://doi.org/10.7652/xjtuxb201503009
2015-01-01
Abstract:The void fraction of high-pressure and high-temperature two-phase flow was measured using differential pressure substitute method under the conditions that the pressures are 11.3,14.2 and21.5 MPa,the mass velocity ranges from 250 to 1 200kg/(m2·s),and the heat flux is from 50to300kW/m2.The comparison between experimental data and results of several classical models was conducted.The experimental data agreed with the Zivi model and the model of China’s national standards for hydrodynamic calculation of power station boiler.The relative error between Zivi model and the experimental data is less than 15%and even less than 10%in high quality region.It can be concluded that the method of differential pressure substitute is suitable for the parameter measurement of high-pressure two-phase flow with high temperature in the vertical ribbed tube.
What problem does this paper attempt to address?