Oil-water two-phase flow measurement based on differential pressure

Long-bo MA,Hong-jian ZHANG,Hong-liang ZHOU,Qing HE
DOI: https://doi.org/10.3785/j.issn.1008-973X.2007.02.038
2007-01-01
Abstract:Flow measurement of oil-water two-phase flow was carried out with a Venturi meter using differential pressure method. Based on Venturi differential pressure and water volume fraction, a model for measuring oil-water mass flowrate was developed, in which the effect of asymmetric density distribution of oil-water two-phase flow was considered and the mixture density was modified. Experimental measurement of oil-water two-phase flow was carried out by Venturis on 25 and 40 mm diameter pipes, respectively. Experimental results showed that when Reynolds number was larger than 3.0 × 10 4, the effect of water volume fraction on the measurement error of the mass flowrate was relatively small and the measurement error of the total mass flowrate was acceptable. And the measurement error of the total mass flowrate was independent of the pipe diameter in the whole oil-water mass ratio.
What problem does this paper attempt to address?