A Flow Rate Measurement Method for Horizontal Oil-Gas-water Three-Phase Flows Based on Venturi Meter, Blind Tee, and Gamma-Ray Attenuation
Yugao Ma,Chao Li,Yanzhi Pan,Yisheng Hao,Shanfang Huang,Yinghuan Cui,Wenbin Han
DOI: https://doi.org/10.1016/j.flowmeasinst.2021.101965
IF: 2.42
2021-01-01
Flow Measurement and Instrumentation
Abstract:Online horizontal oil-gas-water three-phase flow rate monitoring is essential for reliable operations during industrial production. A flow rate measurement method is developed in horizontal oil-gas-water three-phase flows by combining a blind tee, a Venturi meter, and a gamma-ray densitometer. The blind tee is installed at the test section entrance to homogenize the mixture by transforming the horizontal flow to a vertical upward flow. The Venturi meter is used for the total flow rate measurement. The dual-energy gamma-ray densitometer is used for phase holdup measurement. In the present method, blind-tee mixing effects and oil-water mixture slip behavior is essential, which were experimentally analyzed in this work. The phase inversion was found in the oil-water mixture with the increasing of the oil volume fraction. Besides, the addition of the gas reduces the oil-water slip ratio. For the range of 0–35% and 65–100% oil fraction in the oil-water liquid, the oil-water mixture can be well treated as a pseudo homogenous liquid with a slip ratio of 0.9–1.1. A three-phase flow rate model is then established for these conditions. The method was validated by horizontal oil-gas-water three-phase flows with average relative errors of 3.2% for the total flow rates, 4.3% for the gas flow rates, 11.5% for the oil flow rates, and 7.8% for the water flow rates.