A New Method of Measuring the Oil–air–water Three-Phase Flow Rate

Yanjun Wang,Haoyu Li,Xingbin Liu,Lei Li,Chunhui Huang,Jinhai Hu
DOI: https://doi.org/10.1080/00986445.2016.1246438
2016-01-01
Chemical Engineering Communications
Abstract:Oil-air-water three-phase flow patterns in small-diameter vertical measurement channels are complex, making it difficult to establish techniques for interpretation of logging information. In this study, dynamic experiments involving oil-air-water three-phase flows were performed using a novel production logging tool that combined a petal-type turbine flowmeter, a conductance sensor, and an optical fiber sensor in a simulation well. Sensor response characteristics were researched, and a new method of measuring the oil-air-water three-phase flow rate was proposed. The measurement range and resolution of the gas flow rate were 3-20 and 1 m(3)/d, respectively, and the relative error range of gas flow rate interpretation was 5-10%. The measurement range and relative interpretation error range of the total liquid flow rate were 10-60 m(3)/d and 5-10%, respectively. The measurement range and resolution of the water cut were 50-100% and 2%, respectively. The absolute error range of interpretation of the water cut ranged from 3.2% to 5%. Currently, the technique is valid for laboratory use under ideal conditions.
What problem does this paper attempt to address?