Double parameter measurement of steam-water two-phase flow by using differential pressure noise of orifice

ShuoPing Zhong,Yunxian Tong,Wenran Wang
1997-01-01
Abstract:For the on-line measurement of steams in the heavy oil heating-recovery process, the study on the differential pressure noise of orifice in two-phase flow has been achieved and a theoretical model has been obtained for measuring mass flowrate as well as quality of steam-water two-phase flow. A meter based on a micro-processor 8098, measuring double parameters of steam-water two-phase flow, has been developed. Using only a single standard orifice and suitable pressure and differential pressure transmitters, the on-line measurement of the double parameters of steam-water two-phase flow, i.e., mass flowrate and quality, can be obtained. The measured relative root mean square error of mass flowrate and quality are ��9.0% and ��6.5% respectively.
What problem does this paper attempt to address?