Hydrodynamic characteristic calculation for a 600 MW unit onceGthrough tower boiler

Yanshuang BI,Shaofei WANG,Yanrong SHEN,Dong YANG
DOI: https://doi.org/10.3969/j.issn.1002-3364.2015.01.025
2015-01-01
Abstract:Such problems as serious salgging,frequent tube burst,superheater and reheater overtemperature and insufficient pulverizing system capacity occurred in the 600 MW unit once-through tower boiler in Yuanbaoshan Power Plant.Thus,the water wall of this boiler was optimized.According to the structural characteristics of the water wall and the heat load distribution features in the furnace after the transforma-tion,the water wall was divided into the flow circuit,pressure point and flow network system comprised of connected tubes.On the basis of the mass conservation equation,momentum balance equation and energy conservation equation,the mathematic models for pressure drop and outlet steam temperature of water wall tube in subcritical boiler were established.Moreover,the total pressure drop in rising system and the outlet steam temperature of the upper and lower water wall were calculated,under conditions with different unit loads.The results show that,the temperature of the inner pipes,outer pipes,middle points and the rear fin are all reliable,which can ensure the boiler work safely.
What problem does this paper attempt to address?