Calculation on Water Wall Temperature in the Furnace of a 1000 MW Ultra-supercritical Tower Boiler

朱明,张忠孝,周托,赵超,滕叶
DOI: https://doi.org/10.3969/j.issn.1674-7607.2012.01.001
2012-01-01
Abstract:Taking the 1 000 MW ultra supercritical tower boiler in a certain power plant as an object of study,based on calculation results of one-dimensional section,the water wall temperature distribution was obtained under varying working conditions,by dividing the primary combustion zone,simplifying the model of heat radiation in furnace and of heat transfer in tube,under premise that relevant engineering requirements were satisfied.The temperature distribution was compared with actual measurements later on.Results show that the water wall temperature forms two peaks along the height direction of furnace,whereas along the width direction,the peak of temperature wave appears in the furnace center.The water wall temperature drops with reducing load.Since the root-mean-square error between calculated data and actual measurements is not more than 5.83%,the model can be used to predict the distribution of water wall temperature.This may serve as a reference for design and operation of similar boilers.