ICOPE-15-C136 Study on Temperature Characteristics of Water Wall in 700℃ Ultra Supercritical Boiler

Xianyao Shang,Zhongxiao Zhang,Jiancong Dong,Ye Teng,Haojie Fan
DOI: https://doi.org/10.1299/jsmeicope.2015.12._icope-15-_198
2015-01-01
The Proceedings of the International Conference on Power Engineering (ICOPE)
Abstract:A coupling two-dimensional calculation model is established based on regional method to calculate the temperature distribution of water-wall tube surface and steam in tube under ultra-supercritical conditions (27.9MPa, 600℃ and 35MPa, 700℃). Taking convection and radiation heat transfer into consideration, the coupling heat transfer model of combustion and hydrodynamics shows good accuracy for ultra-supercritical conditions of 27.9MPa, 600℃ compared with data got in operational units with average error being 2.66%, 2.11% and 2.38% under three working load. For ultra-supercritical conditions of 35MPa, 700℃, the heat flux at the pulverized coal burner zone is higher than that of the upper and lower furnace. The circumferential temperature distribution of water-wall shows parabola-shape with two peaks and ranges from 534℃〜619℃under BMCR condition. The maximum temperature reaches to 619℃ so that material with permitted temperature higher than 650℃ is recommended for water wall tube for safety operation in 5% security margin. Substance under BMCR does not show phase transition along the water-wall tube which indicates that the substance has gone through the large specific heat region before getting into the water wall.
What problem does this paper attempt to address?