An Experimental Study on Distribution Characteristics of High Pressure Steam-Water Two-Phase Flow

Yuqin Zhu,Weishu Wang,Qincheng Bi
DOI: https://doi.org/10.1166/asl.2011.1495
2011-01-01
Advanced Science Letters
Abstract:Supercritical pressure once-through boiler for sliding pressure operation is the most advanced thermal power unit in the world today and represents the trends of China's development of the thermal power construction. When the boiler is running at lower power loads or during start-up, after leaving middle distribution headers of the transitional water walls, the mixture of steam-water will redistribute in the vertical water wall tubes. If a large flow deviation in the vertical water wall tubes and a large steam temperature deviation at the exit of vertical water wall tubes occur, they will affect the boiler's safety. To develop 600 MW supercritical pressure once-through boilers with sliding pressure operation, in this paper, a systematic experiment had been performed to study the distribution characteristics of two-phase flow in the middle distribution header and vertical water wall tubes at a high pressure steam-water test loop for the first time. The condition of the test parameter is as follows: the pressure p = 10 similar to 21 MPa, the mass velocity in inlet tube of distribution header G = 400 similar to 1200 kg/(m(2) . s), and the inlet steam quality x = 0.7 similar to 1.0. The research results not only have significant engineering meaning to ensure the boilers working safely and operating at high efficiency, but also will provide design basis for the supercritical pressure boilers with intellectual property rights in China.
What problem does this paper attempt to address?