Effect of steam quality on two-phase flow in a natural circulation loop

Haijun Jia,Shaorong Wu,Ning Wang,SiMin Yao
1996-01-01
Nuclear Science and Techniques/Hewuli
Abstract:Test pressures are 1.0approx.4.0 MPa, heating powers 27approx.190 kW, inlet subcoolings 5approx.80��C, water used as coolant, and steam quality at the outlet of test section is less than 0.05. These test conditions cover the parameters for a typical 200 MW heating reactor. The experimental results show that the steam quality is the dominant factor in a natural circulation system with low pressure and low steam quality about the effect of system pressure, heating power and inlet subcooling on the flow rate, relative oscillatory amplitude and oscillatory region of flow rate.
What problem does this paper attempt to address?