Effect of heat flux on the stability of two phase flow natural circulation with low steam quality

Haijun Jia,Shaorong Wu,Ning Wang,SiMin Yao
1995-01-01
Abstract:Using water as coolant, the effect of heating power on the flow rate, relative oscillatory amplitude and oscillatory period of flow rate in a natural circulation system with low pressure and low steam quality has been carried out on the test loop HRTL-200 (heating reactor test loop). Test pressures ranged from 1.0 to 2.5 MPa, heating powers 27-190 kW, inlet subcoolings 5-80��C, and steam quality at the outlet of the test section was less than 5% (the test conditions covered the parameters which were typical for a 200 MW nuclear heating reactor). The experimental results showed that as the heating power increased the mass flow rate increased non-linearly, the oscillatory period decreased, the maximum relative oscillatory amplitude changed a little, and the subcooling region in which the flow was unstable moved toward the direction of the larger subcooling value.
What problem does this paper attempt to address?