NONLINEAR MATHEMATICAL MODEL FOR FLOW RATE DISTRIBUTION IN THE PARALLAR TUBES OF BOILER SUPERHEATER/REHEATER AND THE CALCULATION METHOD OF TUBE SURFACE TEMPERATURE

YANG Dong,CHEN Ting-kuan,LI Hui-xiong,LIU Lin-zhi,JI Xian-lei
DOI: https://doi.org/10.3321/j.issn:0258-8013.2001.05.008
2001-01-01
Abstract:A nonlinear mathematical model is developed to determine the flow rate distribution in the parallel tubes of boiler superheater and reheater by depending on the relation of pressure drop among individual tubes and accounting for the static pressure variations in the inlet and outlet headers. Compared with the flow calculation model presently used by boiler manufactures, the proposed one introduces fewer experience parameters, which may result in higher accuracy. Also, flow rate in each tube can be obtained. As the dangerous position needed to be verified has been identified with the known heat flux profile and the characteristics of flow rate distribution, the metal tube temperature of the position can be obtained. This temperature calculation method avoids the non-correspondence between the flow rate and heat flux, which may exists in that used by boiler manufactures, and was employed to calculate the tube temperature of dangerous position that concerns with the retrofit scheme of Superheater 1 of tower type coal-fired 330 MW once-through boiler in Pucheng Power Plant for 100% and 50% operation load. The results show that all the verified temperatures are within the limit of those permitted by metal material.
What problem does this paper attempt to address?