Experimental Verification on the Assessment System of Outdoor Insulation State of Saturated Moist Insulator

王黎明,周凯,赵晨龙,梅红伟,戴罕奇,周志成
2012-01-01
Abstract:In order to prevent pollution flashover,we introduced an assessment system on the outer insulation state of insulator.The assessment system integrated insulator type,voltage level,relative humidity,maximum leakage current and other effects,so it could determine the outer insulation status of insulator,especially the flashover voltage.Thus the pollution flashover could be prevented.Moreover,on the basis of the system,we investigated the relationship between equivalent salt deposit density(ESDD),insulator number,leakage current under service voltage,and pollution flashover voltage,and compared the estimated pollution flashover voltage and real pollution flashover voltage.The results show that,when the numbers of XWP2-160insulators are 28,21,and 14,their maximum relative errors will be 4.6%,6.6%,and 5.5%,respectively,and the results verify the reliability and accuracy of the system.