Prediction of Pollution Flashover Voltage Based on Leakage Current under AC Operating Voltage

MEI Hongwei,WANG Liming,GUAN Zhicheng,MAO Yingke
2012-01-01
Abstract:This paper presented a model to predict the AC flashover voltage of contaminated suspension insulators.The prediction method is based on the maximum leakage current under AC operating voltage.Three kinds of widely used suspension insulators were tested in various contamination states such as pollution layers with different equivalent salt deposit density(ESDD),different composition of the conductive components,different non-soluble deposit density(NSDD) and different pollution distribution states to simulate the contamination states in nature.The effective ESDD was proposed and calculated.Influences of contamination states to maximum leakage current and flashover voltage were studied.Then,the relationships between flashover voltage and leakage current in these states were presented.Finally,considering the difference of insulator profiles,a new parameter is defined and a model to estimate the flashover voltage based on this parameter is developed.The model could be used in all kinds of suspension insulators in different contamination states and was validated by the test results.
What problem does this paper attempt to address?