Simulation study of active power filter based on a novel reactive and harmonic current detection method

Wang Chunlei,Zhang Dairun
DOI: https://doi.org/10.3969/j.issn.0258-7998.2012.03.024
2012-01-01
Abstract:This paper adopts a detection method that combines the advantages of both ip-iq detection method based on instantaneous reactive power theory and closed-loop adaptive detection method.This method is better compared to both in terms of robustness and dynamic response speed.And as the inverter adopts three bridge-arm capacitor mid-point structure,the inverter's DC voltage stability and upper and lower capacitor's uniform voltage control are analyzed.And it is with the reactive and harmonic current detection combine to form a double-loop structure to further enhance the compensation effect,then the synthesis of instructions current and tracking control are briefly described.Finally,the system is simulated with Matlab/Simulink,and then the simulation results validate the correctness and validity of the method.
What problem does this paper attempt to address?