Determination of melitracen in human plasma by HPLC-MS

SHU Wan-qing,ZUO Xiao-cong
DOI: https://doi.org/10.3321/j.issn:1001-5213.2008.14.008
2008-01-01
Abstract:OBJECTIVE To develop an HPLC-MS method for the determination of melitracen in human plasma.METHODS Melitracen and the internal standard terfenadine added as internal standard were extracted from the patient plasma using liquid-liquid extraction by ethyle acetate,then separated on a Thermo Hypersil-HyPURITY C18(150 mm×2.1 mm,5 μm)with a mobile phrase of 10 mmol·L-1 ammonium acetate-methanol-acetonitrile (41∶5∶54) at a flow rate of 0.25 mL·min-1.HPLC-MS-ESI+ was performed in the selected ion monitoring(SIM) mode using target ions at m/z 292(melitracen) and m/z 474(IS).RESULTS The linear concentration range of the calibration curves for melitracen was 0.78-50.0 μg·L-1(r=0.999 8).The limit of quantitation of melitracen was 0.78 μg·L-1.The average recovery was in the range of 92.3%-101.0%.Within-day and between-day RSDs were less than 15%(n=5).CONCLUSION The method is sensitive,accurate and suitable for the determination of melitracen in Human Plasma.
What problem does this paper attempt to address?