Liquid chromatographic method for the determination of rizatriptan in human plasma.

Jun Chen,Xinguo Jiang,Wenming Jiang,Ni Mei,Xiaoling Gao,Qizhi Zhang
DOI: https://doi.org/10.1016/j.jchromb.2004.02.021
IF: 3.318
2004-01-01
Journal of Chromatography B
Abstract:A high-performance liquid chromatographic (HPLC) method with fluorescence detection has been developed for the determination of rizatriptan in human plasma. Following a single-step liquid–liquid extraction with methyl tertiarybutyl ether, the analytes were separated using a mobile phase consisting of 0.05% (v/v) triethylamine in water (adjusting to pH 2.75 with 85% phosphoric acid) and acetonitrile (92:8, v/v). Fluorescence detection was performed at an excitation wavelength of 225nm and an emission wavelength of 360nm. The linearity for rizatriptan was within the concentration range of 0.5–50ng/ml. The intra- and inter-day precisions of the method were not more than 8.0%. The lower limit of quantification (LLOQ) was 0.5ng/ml for rizatriptan. The method was sensitive, simple and repeatable enough to be used in pharmacokinetic studies.
What problem does this paper attempt to address?