Determination of TJ0711 hydrochloride in rat plasma by high performance liquid chromatography with fluorescence detection and its application to pharmacokinetics
Zhaoze Fan,Luqin Si,Li Xu,Yiming Ma,Lei Hu,Jun Qiu,Gao Li
DOI: https://doi.org/10.1016/j.jchromb.2010.05.041
IF: 3.318
2010-01-01
Journal of Chromatography B
Abstract:In the present study, a simple and sensitive high performance liquid chromatography with fluorescence detection (HPLC-FD) method was developed to determine TJ0711 hydrochloride, a novel α- and β-receptor blocker. TJ0711 hydrochloride and verapamil hydrochloride (the internal standard) were separated on Knauer Eurospher C18 (250mm×4.0mm i.d., 5μm) column at 50°C. The mobile phase was methanol:perchloric acid (12nM, aq) (56:44, v:v), with a flow rate of 1.0mL/min. The wavelengths of FD were set at 246nm for excitation and 300nm for emission. For plasma samples of rats, the analytes were extracted with acetic ether from alkalinized plasma, and then back-extracted into 10mM dilute sulfuric acid. The linearity was over a concentration range of 20–10,000ng/mL. The intra- and inter-day precisions referred by relative standard deviation were less than 2.0% and 4.3%, respectively. The mean analytical recoveries of TJ0711 hydrochloride at different concentrations (50, 1000 and 8000ng/mL) ranged from 88.3% to 92.9%. The lower limit of quantification (LLOQ) was 20ng/mL. Finally, this method was successfully applied to the estimation of pharmacokinetic parameters of TJ0711 hydrochloride after intravenous doses of 4, 8 and 16mg/kg in rats.