Determination of diphenytriazol (DL111-IT) and its related impurities by RP-HPLC with DAD.

Xiangjun Wang,Tongwei Yao,Su Zeng
DOI: https://doi.org/10.1016/S0731-7085(03)00107-9
IF: 3.571
2003-01-01
Journal of Pharmaceutical and Biomedical Analysis
Abstract:An analytical method was developed for determining diphenytriazol and its related impurities in oil injection by using RP-HPLC with DAD and diazepam as internal standard. The C18 column was used as analytical column. Mobile phase consisted of methanol–potassium dihydrogen phosphate solutions (10 mmol l−1, pH 7.5) (7:3, v/v). The standard curve was linear in the concentration range from 2 to 100 μg ml−1 for diphenytriazol. The analytical method afforded average recoveries of 100.3±1.9% (n=9) and the relative standard deviation (RSD) was less than 2% for within-day and between-day precision. The limit of detection and of quantitation for the assay were 15 and 40 ng, respectively. The method was simple, accurate and allowed to be used as analytical method for the routine quality control of diphenytriazol injection. Diphenytriazol injection showed a high stability to the heat (60°C) and the light (4000 lx).
What problem does this paper attempt to address?