Ventilation and Stator Temperature Field of Bulb Tubular Turbine Generator

Xia Haixia,Li Tao,Yao Yingying,Ni Guangzheng
DOI: https://doi.org/10.19595/j.cnki.1000-6753.tces.2008.07.002
2008-01-01
Abstract:In order to research the coupled problem of stator temperature field and ventilation system fluid field of generator,the three dimensional finite element models of ventilation system fluid field and stator temperature field of a 700 kW bulb turbine generator are presented.According to the hydrodynamics and heat transfer theory,the fluid field of the generator ventilation system is calculated by using the finite element method.Based on the distributions of pressure and velocity of the ventilation system,the coefficients of heat transfer are obtained further.With the losses of different parts,the stator temperature field distributions are calculated.Considering different material designs of stator shell to prevent erosion,their effect on stator temperature are analyzed further.The results show that,when the flux of air flow is satisfied,the calculated ventilation pressure is coincident with the test value.The stator temperature is in the range of the permissible temperature of designed insulation and has enough tolerance.And lacquering on the shell surface is selected as the practical scheme.
What problem does this paper attempt to address?