Comparing Between 3D Finite-element Method and Thermal-circuit Method of Calculating Thermal-resistances in the Thermal Field of Three-gorge Hydrognerator

WANG Hong-yu,SU Peng-sheng,WANG Xiang-heng
DOI: https://doi.org/10.3969/j.issn.1000-3983.2007.01.004
2007-01-01
Abstract:In order to calculate the thermal-field of Three-gorge hydrogenerator using 3D thermal-network,this paper presents the structure of 3D thermal-network on an unit of stator core and an unit of stator ending.The parameters of thermal-resistances between nodes of stator core and stator ending are calculated by using 3D finite-element method and thermal-circuit method.And the relative errors of calculation gotten from these two methods are analyzed.The analysis results show that the thermal resistances among nodes,which have insulation region,are not fit to be calculated by the thermal-circuit method,but the 3D finite element method.This kind of thermal resistances occupied nearly half of all thermal resistances in 3D thermal network of Three-gorge hydrogenerator.And the calculation results of 3D thermal-network with the parameters calculated by using 3D finite-element method are closer to the calculation results of 3D finite-element method than that of thermal-circuit method through calculating of 3D thermal-field of stator ending-winding.So,it is necessary to calculate the thermal resistances by using 3D finite element method.
What problem does this paper attempt to address?