Calculation on 3D Static Thermal-flied of Three-gorge Half-cooled Hydrogenerator Stator by Using Thermal-liquid Coupling Element

WANG Hong-yu,SU Peng-sheng,WANG Xiang-heng
DOI: https://doi.org/10.3969/j.issn.1000-3983.2006.06.001
2006-01-01
Abstract:The thermal-liquid coupling element is used in the boundary between cooling-water and hollow-strand,and the nonlinearity of its convection coefficient is taken into account.The heat-generation rate(volume-density of copper-loss) with temperature is considered.This paper calculates the 3D thermal-flied of end-winding and core section of Three-gorge hydrogenerator stator.It is shown that the method is valid because the result of calculation is fit to the flied data.The temperature of tooth of stator core is higher than that of yoke of stator core;the temperature between the upper-bar and the lower-bar is greatly influenced by the temperature of cooling-water,and is approximately equal to the average of maximum temperatures of upper-bar and the lower-bar;95.66% of copper-loss and 25% of core-loss of stator are taken away by the cooling-water,so the cooling effect of cooling-water is vital for the half-cooled hydrogenerator.