Optimal Analysis on Temperature Field of Stator Ventilation System Based on Longitudinal Vortex Generator

从飞云,董成举,赵威,唐宁,童水光
DOI: https://doi.org/10.3969/j.issn.0559-9342.2018.05.017
2018-01-01
Abstract:A coupled calculation model of ventilation system fluid flow and heat transfer of hydro-generator stator is presented according to hydronamics and heat transfer theory.The fluid field and temperature field of the stator ventilation system is analyzed by using the model,and then the result of temperature analysis is compared with test value to verify the validity of model.To improve the heat transfer of stator,the longitudinal vortex generator (LVG) is set on the wall surface of stator ventilation duct with high temperature,and then the influence of height and attack angle of the LVG on heat transfer is analyzed.The temperature field of new model is analyzed with different inlet air speed and the results show that the LVG has greatest effect on temperature decrease when the angle of attack is 45 ° and the height is 5 mm.