Analysis and Countermeasure for Unknown Scale Substances on Evaporator of Gas Turbine Generating Unit

HE Bin,YANG Zhen-guo
DOI: https://doi.org/10.3969/j.issn.0427-7104.2007.03.008
2007-01-01
Abstract:The normal operation of large-scale gas turbine generating unit was affected by metal corrosion and scaling.The unknown scale substances on the evaporator of the gas turbine of Shanghai Baosteel Corporation were characterized and analyzed using scanning electron microscope,X-rays diffraction spectrometer,energy dispersive spectrometer,thermogravimetric analysis and inductively coupled plasma spectrometry.It showed that the scale substances were the mixtures of alkaline iron sulfate and this kind of corrosion was sulfate corrosion at a high temperature of 300 ℃.In addition,the mechanism and cause of corrosion were discussed and the corresponding preventive measures were also proposed.