Abstract:An experimental study was performed to clarify the thermal mixing characteristics of coolant in the core bottom structure (CBS) of the gas-cooled high temperature engineering test reactor (HTTR) being developed in JAERI. It was carried out using a one-seventh scale test model of the CBS including a hot plenum and an outlet hot gas duct, and water was used as the test fluid. Hot and cold water were poured into the test model and the temperature distributions of the mixed water were measured. The range of the experiment covers Reynolds numbers from 40000 to 100000 and the temperature difference between the hot and cold water ranged from 20 to 40 ° C. The water was mixed sufficiently in the plenum when hot water flowed in a central inlet nozzle of the test model. The mixing of water was insufficient and hot water flowed along the wall of the outlet nozzle when the hot water flowed in a circumferential inlet nozzle. The mixing promoter was not effective enough to mix the water in the plenum.