Determination of pseudoephedrine hydrochloride in human plasma by HPLC

Qu Jian
2006-01-01
Abstract:Aim To establish a sentive and specific method for determination of pseudoephedrine hydrochloride in human plasma.Methods Pseudoephedrine was extracted from alkaline plasma with t-butyl methyl ether as the base form,and was back-extracted into 0.5% hydrochloride solution.The drug was determined by RP-HPLC.The LC-6A HPLC apparatus and Kromasil C_(18) column were used with mobile phase of 0.01 mol·L~(-1) KH_(2)PO_(4)(pH6.5)-acetonitrile(62∶38),The flow rate was 1.0ml·min~(-1) and the detection wavelength was 210 nm.Results The linear range of pseudoephedrine was 0.015~1.60 mg·L~(-1),(Y=4631.8X+3.76,r=0.999 8),The average recovery of pseudoephedrine in human plasma was 101.7%.The within-day RSD were 3.41%~4.25%,and the daytime RSD were 6.47%~9.66%.Conclusion The method was specific,sensitivity,simple and suitable for the determination of human plasma pseudoephedrine and pharmacokinetic researches.
What problem does this paper attempt to address?