NUMERICAL SIMULATION OF PRIMARY AIR MEASUREMENT AT THE INLET OF COAL MILL

CHANG Yijun,WANG Xiaobing,ZHANG Bo,NIU Guoping
DOI: https://doi.org/10.3969/j.issn.1002-3364.2012.12.048
2012-01-01
Abstract:Because of the short distance between the hot-cold air mixed segment and the measuring cross section,the hot air was unable to fully mixed with the cold air,so the stability and accuracy of measurement for primary air at inlet of the coal mill was relatively low.Through numerical simulation,the guide blade was installed in primary air pipe where hot and cold air mixed together,to increase the penetration depth of the cold air.The temperature difference of the measured cross section dropped from 166 ℃ to 22 ℃,and the variation range of speed on it decreased from 13-25.8 m/s to 20-22 m/s.After the flow mixed device was installed,the hot and cold air were fully mixed,effectively improving the uniformity of speed and temperature distribution on the measuring cross section.The air flow measurement coefficient was stable and the accuracy was improved obviously.